GE
5ft GE 3-Prong Dryer Power Cord
SKU: WX09X10003
$15.99per item
Current stock at Marietta
Store pickup
NO STOCK AVAILABLE
Check another store or ask us about availability.
Norcross: 1 unit available
Purchase in store, then bring your pickup QR code to the warehouse pickup area. Our staff will scan it, retrieve your order and load your vehicle.
Need transport? Ask us for a referral to an independent local delivery provider. Arrange delivery directly with that provider.
Pickup & transport detailsCheck other stores & update ZIP
- MY STORE
Marietta
NO STOCK AVAILABLE
119 Cobb Parkway North, Suite D, Marietta, Georgia 30062
Norcross
1 unit available
6755 Jimmy Carter Blvd, Norcross, Georgia 30071
Checking your Project List…
Adding an item does not reserve stock.
Questions about this item?
Call Marietta · (770) 874-2254Call Norcross · (770) 758-3223Ask about this itemAsk us to confirm this item’s condition and pickup availability. Item reference: WX09X10003. Purchases are completed in store. In-store pickup only.
Specifications
Details
- Product Type
- Three-Wire Electric Dryer Power Cord
- Recommended Use
- Compatible 30-Amp Electric Dryer Connection
Bath Hardware Product Information
- Overall length (inches)
- 60
Product details
The GE WX09X10003 is a five-foot, 30-amp dryer power cord with a three-wire configuration. It is an electrical connection accessory for a compatible electric dryer and matching receptacle. The five-foot length provides room to route the connection behind the dryer, helping accommodate a laundry layout in which the wall outlet is offset from the appliance's terminal area.
A three-prong plug identifies the outlet configuration this cord is intended to match. The appliance end connects at the dryer's designated electrical terminal block using the installation method specified for that dryer. Selecting a cord requires matching the plug to the actual receptacle and confirming the dryer's electrical requirements, rather than choosing by cord length or appliance brand alone.
The WX09X10003 part number distinguishes this GE cord from four-wire versions and other available lengths. It serves a specific dryer hookup need, so the existing outlet, terminal arrangement and installation instructions should be reviewed before the connection is made. Once correctly matched, the cord supplies the dedicated electrical link between the compatible dryer and its household laundry outlet.
Buying guide
Choosing this product
WX09X10003 is a five-foot, 30-amp, three-wire dryer cord for a compatible electric dryer and matching receptacle.
Match the cord to the appliance instructions and the receptacle configuration. The number of prongs and nominal cord length are separate specifications. A dryer cord and a range cord should be compared by their documented application and electrical rating. Identify the actual receptacle and appliance connection before selecting a cord from its appearance.
Start with the appliance model and the existing connection, then compare the accessory specifications. Check the intended application, length and connection arrangement as separate details. Similar-looking accessories can have different uses. Keep the appliance instructions available while comparing choices, and ask the installer to resolve a mismatch before replacing the existing connection.
A replacement project and a new installation may have different requirements. Record what is already installed and why it is being replaced. If the appliance or its location is changing, check the complete new arrangement rather than assuming the old accessory remains suitable. Compare the documented requirements with the actual site measurements.
Planning the fit and layout
Check the actual outlet position against the five-foot routing length before placing the dryer in the laundry space.
Measure the route between the appliance connection point and the receptacle without stretching the cord or forcing a tight bend. Check the appliance instructions for the connection arrangement and required strain relief. Leave space for the appliance to reach its installed position without pinching the cord against cabinetry or a wall.
Make a simple sketch showing the appliance, the supply connection and the planned route between them. Measure along that route rather than straight through cabinetry or another obstruction. Mark the points where the accessory may bend or pass close to a fixed surface. Compare those details with the instructions for the exact accessory and appliance.
Check the arrangement with the appliance both accessible for installation and in its final position. The route may change as the appliance is moved. Identify surfaces that could trap or damage the connection, and keep any required access point reachable. Have the installer check the usable space before deciding that the nominal accessory length is sufficient.
Installation & care
Installation and everyday care
Have the cord connected according to the dryer terminal-block instructions and the requirements of the installation.
Have a qualified installer connect the cord according to the appliance instructions, the cord labeling and the site requirements. Prong count alone does not establish that the connection is suitable. Follow the documented terminal and strain-relief arrangement, and disconnect the electrical supply before installation or inspection of an open connection.
Read the accessory instructions together with the appliance installation instructions. They describe different parts of the same connection. Use the documented fittings, securing method and routing requirements for the actual application. Have a qualified installer resolve any discrepancy between the existing site arrangement and those instructions before completing the connection.
Keep the work area accessible while the connection is fitted and checked. Protect the accessory from being crushed or damaged as the appliance is moved into position. Follow the documented process for restoring the supply and testing the installed arrangement. Any required inspection should include the connection in its final operating position.
Product FAQs
How do I plan access and future maintenance?
Preserve access behind the dryer and route the cord so appliance movement will not trap it.
Keep the cord identification with the appliance model and installation records. During accessible inspection, look for a cord trapped behind the appliance or exposed to damage. If the cord or connection is damaged, use the appliance service instructions and a qualified installer to select the correct replacement rather than changing plug configurations by appearance.
Keep the accessory and appliance model information together in the project records. Photograph an accessible connection after installation if it will assist later servicing. Follow the appliance instructions for disconnecting the supply before work that opens a connection. Use the exact requirements when choosing a replacement rather than matching only the appearance.
What should I check before ordering?
Confirm the three-prong outlet configuration and exact WX09X10003 part number when ordering the cord.
Check the complete cord model, intended appliance application, prong arrangement and documented rating before ordering. Compare its length with the planned connection route. Confirm the cord and any connection components actually present in the individual listing. Ask the installer to identify any separately required hardware by its exact specification.
Compare the complete accessory model, intended application, length and connection details before ordering. Bring the appliance model and measurements when asking about fit. The description of a compatible connection does not establish that every installation uses the same arrangement. Check the actual site and the appliance instructions together.
Product guides
Customer questions & answers
Questions about this product and the selected option. For current stock or pickup arrangements, contact AHL.
0 published questions
No published questions yet. Be the first to ask about this product.